Whether stainless steel storage tank can be used in anti-corrosion operation


Release time:

2019-08-22

When the anti-corrosion ability of the goods is used, the anti-corrosion effect directly affects the service life, so we should pay attention to the anti-corrosion operation in the industry. In the use of stainless steel storage tank should pay attention to the following matters: 
1. Anti-static equipment shall be set when the stainless steel storage tank is filled with high resistance solvent.
2. The stainless steel storage tank shall not impact and bump the equipment body during the equipment process.
3. Because the raw material of the all-plastic flange is softer than the steel plate, the user should check the sealing function of the storage tank equipment before use, and add liquid to investigate whether it is leaking. The storage tank containing chemical liquid shall be tested for leakage with water to avoid loss.
4. The stainless steel storage tank is normal temperature and pressure storage tank. Steel plastic composite storage tank using temperature is -40 ℃ ~ 98 ℃, polyethylene plastic storage tank using temperature is -40 ℃ ~ 60 ℃.
5, storage tanks in the storage of chemicals, the storage items should be marked. There shall be drainage trench and dilution equipment near the place where the storage tank is placed.
6. The perfusion and output of the equipment can be turned open to avoid damage to the equipment.
7, equipment and equipment use environment should be away from the source, so as not to touch the open flame.
8, the lower part of the storage tank if there is a joint or flange connection of the pipe to be perpendicular to the barrel wall, with soft connection, so as to avoid full of liquid, the barrel wall up and down uneven swelling caused by joint connection damage caused by leakage, severe damage to the joint and barrel body.
9. When the liquid inlet is higher from the bottom of the tank, the liquid inlet should be bent to the tank wall to allow the liquid to fall along the tank wall to reduce the impact on the bottom.
10. Pipes and accessories connected with the equipment shall not directly act on the equipment. During lifting, the receiving and entering holes on the equipment shall not be used as the focal point.
11. Acid-proof gaskets shall be selected and sealed for receiving on the equipment, and gaskets shall be replaced in time.
12. The use and protection of the equipment shall be performed with reference to relevant national regulations.