The company has established the enterprise goal of "survival by quality, reputation by quality, and development by quality. Strengthen the training of technical personnel, and constantly enrich the first-line technical force to ensure the normal operation of the quality assurance system.

Precautions of high shear emulsifying pot


Release time:

2019-07-29

Note: 1, homogeneous cutting head due to the high speed, not in the empty state of operation, so as not to affect the degree of sealing after local heating. 2. The ground wire is reliably grounded to ensure the safety of electricity use. 3. The homogenizer is reversed from top to bottom. After the motor is wired or when it is not used for a long time, it should be inching to try to turn. The emulsification cylinder is reversed from top to bottom, and the stirring blade is reversed from top to bottom. During debugging, the homogenizer shall be operated after inching and stirring for trial rotation, and then the homogenizer shall be operated after confirmation. 4, each time before the start of stirring should be inching, check the stirring scraping wall is abnormal, if there should be immediately ruled out. 5, before mixing vacuum work must check whether the pot and

Note:
1, homogeneous cutting head due to the high speed, not in the empty state of operation, so as not to affect the degree of sealing after local heating.
2. The ground wire is reliably grounded to ensure the safety of electricity use.
3. The homogenizer is reversed from top to bottom. After the motor is wired or when it is not used for a long time, it should be inching to try to turn. The emulsification cylinder is reversed from top to bottom, and the stirring blade is reversed from top to bottom. During debugging, the homogenizer shall be operated after inching and stirring for trial rotation, and then the homogenizer shall be operated after confirmation.
4, each time before the start of stirring should be inching, check the stirring scraping wall is abnormal, if there should be immediately ruled out.
5. Before stirring and vacuuming, be sure to check whether the pan is flat with the pan cover, whether the pan mouth and the material port cover are tightly covered and reliably sealed.
6. Before the vacuum pump is shut down, the ball valve in front of the vacuum pump should be closed.
7. The vacuum pump can be started under the sealing condition of the homogeneous pot. If there is a special need to open the atmosphere to start the pump, the operation can not exceed 3 minutes.
8. The equipment must be cut off before any maintenance or cleaning.
9, high shear emulsifying pot must not be in the operation of the equipment into the kettle, in order to prevent accidents.
10. If there is any different response during the operation, stop the operation immediately, and start the machine only after the reason is found out.