Management specification for cleaning, disinfection and verification of emulsifying pot


Release time:

2019-06-04

1.0 Objective: To ensure that the cleaning and disinfection of the emulsifying pot, verify the standard operating procedures, and ensure that the quality characteristics of the key control points of the production process meet the requirements. 2.0 range: emulsifying pot used between emulsifying. 3.0 division of powers and responsibilities: the emulsification room of the 3.1 factory affairs department is responsible for the cleaning and disinfection of the emulsifying pot. The microbiological inspector of the 3.2 Quality Assurance Department is responsible for the verification of the emulsifying pot after disinfection. 4.0 Operation Procedure: 4.1 Cleaning and Disinfection Time: 4.1.1 Non-continuous Production of the Same Product; 4.1.2 Production of different products; 4.1.2 Production of different products; 4.2 cleaning method: after the production of emulsifying pot is completed, use it first

1.0 Objective: To ensure that the cleaning and disinfection of the emulsifying pot, verify the standard operating procedures, and ensure that the quality characteristics of the key control points of the production process meet the requirements.
2.0 range: emulsifying pot used between emulsifying.
Distinction of 3.0 rights and responsibilities:
The emulsifying room of the 3.1 plant affairs department is responsible for the cleaning and disinfection of the emulsifying pot.
The microbiological inspector of the 3.2 Quality Assurance Department is responsible for the verification of the emulsifying pot after disinfection.
4.0 operating procedures:
4.1 cleaning and disinfection time:
4.1.1 non-continuous production of the same product;
4.1.2 Production of different products;
4.1.2 Production of different products;
4.2 cleaning method: after the production of the emulsifying pot, first use scraper and cotton cloth to clean up the remaining raw materials, then use tap water to wash the stirring paddle and the pot wall to ensure that there are no residues of raw materials, paste, etc. in the pot, and finally use purified water to clean. after cleaning, clean and verify (see 4.4). if the verification result meets the requirements, disinfect. if the verification result does not meet the requirements, repeat the 4.2 steps, disinfection shall not be carried out until the verification results meet the requirements;
4.3 disinfection methods:
4.3.1 After the cleaning verification meets the requirements, put an appropriate amount of purified water into the pot, heat it to 85±1 ℃ with steam, keep it for 30 minutes, drain the purified water or clean other emulsifying pots;
4.3.2 During the heating and disinfection process, the emulsifying pot shall be provided with warning signs to prevent others from touching the emulsifying pot and avoid causing harm;
4.3.3 After the disinfection is completed, it is necessary to close all valves and covers, hang the "disinfected" mark, fill in the "Equipment Cleaning and Disinfection Record Form" at the same time, and notify the microbiological testing personnel of the Quality Assurance Department to carry out disinfection verification, and continue to use the emulsifying pot only after they sign on the record form;
4.4 cleaning verification method: take 50ML of the last pot washing water with a 100ml volumetric flask, shake the volumetric flask left and right for 10 times to detect the foam height generated, which is less than 0.5cm, and the clean water is transparent, clear and without fragrance;