News Center

The company has established the enterprise goal of "survival by quality, reputation by quality, and development by quality. Strengthen the training of technical personnel, and constantly enrich the first-line technical force to ensure the normal operation of the quality assurance system.

The correct way of disinfection of emulsifying pot


Release time:

2019-05-17

1. After the cleaning verification meets the requirements, add suitable purified water into the pot, heat it to 85 1C with steam, keep it for 30 minutes, drain the purified water or clean other emulsifying pots. 2. During the heating and disinfection process, the emulsifying pot needs to use warning signs to prevent others from touching the emulsifying pot and avoid injury. 3. After the poisoning is completed, all valves and covers shall be closed, and the "disinfected" logo shall be hung. At the same time, the "Equipment Cleaning and Disinfection Record Form" shall be filled in and the microbiological testing personnel of the Quality Assurance Department shall be notified to carry out disinfection verification. The emulsifying pot can be used only after it signs the record form. In addition, after the end of the production of imported cosmetics emulsifying pot, the first

1. After the cleaning verification meets the requirements, add suitable purified water into the pot, heat it to 85 1C with steam, keep it for 30 minutes, drain the purified water or clean other emulsifying pots.
2. During the heating and disinfection process, the emulsifying pot needs to use warning signs to prevent others from touching the emulsifying pot and avoid injury.
3. After the poisoning is completed, all valves and covers shall be closed, and the "disinfected" logo shall be hung. At the same time, the "Equipment Cleaning and Disinfection Record Form" shall be filled in and the microbiological testing personnel of the Quality Assurance Department shall be notified to carry out disinfection verification. The emulsifying pot can be used only after it signs the record form.
In addition, after the production of the imported cosmetic emulsifying pot is completed, the remaining raw materials are first cleaned with scraper and cotton cloth, then the stirring paddle and the pot wall are washed with tap water to ensure that there are no residues of raw materials, paste, etc. in the pot, and finally the pot is cleaned with purified water. After the cleaning is completed, the cleaning verification shall be carried out. If the verification result meets the requirements, the disinfection shall be carried out.